• Features

    Device type Photoelectric sensors
    Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
    Dimensions (W x H x D) 12.2 mm x 49.8 mm x 23.6 mm
    Housing design (light emission) Rectangular
    Mounting hole M3
    Sensing range max.

    0 m ... 4.5 m 1)

    2)

    Sensing range

    0 m ... 2 m 1)

    2)

    Type of light Visible red light
    Light source Laser 3)
    Light spot size (distance) Ø 1 mm (500 mm)
    Wave length 650 nm
    Laser class 1 (IEC 60825-1 / CDRH 21 CFR 1040.10 & 1040.11)
    Adjustment Single teach-in button
    AutoAdapt
    Special applications Detecting small objects, Detecting transparent objects
    • 1) Reflective tape REF-AC1000.
    • 2) To ensure reliable operation, we recommend using REF-AC1000 reflective tape or reflective-tap reflectors such as P41F, PLV14-A, PLH25-M12, or PLH25-D12. Reflectors with large-scale triple structures must only be used if deemed suitable for the application.
    • 3) Average service life: 50,000 h at TU = +25 °C.
  • Mechanics/electronics

    Supply voltage 10 V DC ... 30 V DC 1)
    Ripple < 5 Vpp 2)
    Current consumption 30 mA 3)
    Switching output PNP 4)
    Output function Complementary
    Switching mode Light/dark switching 4)
    Output current Imax. ≤ 100 mA
    Response time ≤ 0.5 ms 5)
    Switching frequency 1,000 Hz 6)
    Connection type Male connector M8, 4-pin
    Circuit protection

    7)

    8)

    9)

    Protection class III
    Weight 13 g
    Polarisation filter
    Housing material Plastic, VISTAL®
    Optics material Plastic, PMMA
    Enclosure rating

    IP66

    IP67

    IP69K

    Special feature Detecting transparent objects
    Ambient operating temperature –10 °C ... +50 °C
    Ambient operating temperature extended –30 °C ... +55 °C 10) 11)
    Ambient temperature, storage –30 °C ... +70 °C
    UL File No. NRKH.E181493
    • 1) Limit values when operated in short-circuit protected network: max. 8 A.
    • 2) May not exceed or fall below Uv tolerances.
    • 3) Without load.
    • 4) Q = light switching.
    • 5) Signal transit time with resistive load.
    • 6) With light/dark ratio 1:1.
    • 7) A = VS connections reverse-polarity protected.
    • 8) B = inputs and output reverse-polarity protected.
    • 9) C = interference suppression.
    • 10) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
    • 11) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.
  • Safety-related parameters

    MTTFD 655 years (EN ISO 13849-1) 1)
    DCavg 0 %
    • 1) Mode of calculation: Parts-Count-calculation.
  • Classifications

    ECl@ss 5.0 27270902
    ECl@ss 5.1.4 27270902
    ECl@ss 6.0 27270902
    ECl@ss 6.2 27270902
    ECl@ss 7.0 27270902
    ECl@ss 8.0 27270902
    ECl@ss 8.1 27270902
    ECl@ss 9.0 27270902
    ECl@ss 10.0 27270902
    ECl@ss 11.0 27270902
    ETIM 5.0 EC002717
    ETIM 6.0 EC002717
    ETIM 7.0 EC002717
    ETIM 8.0 EC002717
    UNSPSC 16.0901 39121528
SKU 1058234
Brand Sick

Be The First To Review This Product!